Bellbrook – (NSW) – Selenium

2008-2013: Bellbrook Selenium 0.005mg/L (max), 0.0011mg/L (mean)

Based on health considerations, the concentration of selenium in drinking water should not exceed 0.004 mg/L (2011-2025 guideline 0.01mg/L). “General description Selenium (Se) and selenium salts are widespread in the environment. Selenium is released from natural and human-made sources (such as the burning of coal). Selenium is also a by-product of the processing of sulfide ores, chiefly in the copper refining industry. The major use of selenium is in the manufacture of electronic components. It is used in several other industries, and selenium compounds are used in some insecticides, in hair shampoos as an antidandruff agent, and as a nutritional feed additive for poultry and livestock. Selenium copper alloys have also been identified as a potential replacement for lead copper alloys in plumbing products. Further information on lead replacements in plumbing products (such as selenium copper alloys) is available in Information Sheet 4.1 – Metal and metalloid chemicals leaching from plumbing products. Selenium concentrations in drinking water source waters are generally very low and depend on local geochemistry, climatic conditions (e.g. drought), pH and the presence of iron salts. Selenium in water is mainly present as inorganic compounds, predominantly selenate. Weathering of rocks and soil may result in low levels of selenium in water, which may be taken up by plants (SLR 2022). Food is the major source of intake for Australians. Cereal and grain products contribute most to intake, while fish and liver contain the highest selenium concentrations.” ADWG 2025

Bellbrook (New South Wales) – Aluminium

2008/13: Bellbrook (New South Wales) Aluminium 0.61mg/L (max), 0.086mg/L (mean)
 
Australian Guideline: Aluminium 0.2mg/L

According to the ADWG, no health guideline has been adopted for Aluminium, but that the issue is still open to review. Aluminium can come from natural geological sources or from the use of aluminium salts as coagulants in water treatment plants. According to the ADWG “A well-operated water filtration plant (even using aluminium as a flocculant) can achieve aluminium concentrations in the finished water of less than 0.1 mg/L.

The most common form of aluminium in water treatment plants is Aluminium Sulfate (Alum). Alum can be supplied as a bulk liquid or in granular form. It is used at water treatment plants as a coagulant to remove turbidity, microorganisms, organic matter and inorganic chemicals. If water is particularly dirty an Alum dose of as high as 500mg/L could occur. There is also concern that other metals may also exist in refined alum.

While the ADWG mentions that there is considerable evidence that Aluminium is neurotoxic and can pass the gut barrier to accumulate in the blood, leading to a condition called encephalopathy (dialysis dementia) and that Aluminium has been associated with Parkinsonism dementia and amyotrophic lateral sclerosis, the NHMRC, whilst also acknowledging studies which have linked Aluminium with Alzheimer disease, has not granted Aluminium a NOEL (No Observable Effect Level) due to insufficient and contradictory data. Without a NOEL, a health guideline cannot be established. The NHMRC has also stated that if new information comes to hand, a health guideline may be established in the future.

In communication with Aluminium expert Dr Chris Exley (Professor in Bioinorganic Chemistry
The Birchall Centre, Lennard-Jones Laboratories, Keele University, Staffordshire UK) in March 2013 regarding high levels of Aluminium detected in the South Western Victorian town of Hamilton
“It is my opinion that any value above 0.5 mg/L is totally unacceptable and a potential health risk. Where such values are maintained over days, weeks or even months, as indeed is indicated by the data you sent to me, these represent a significant health risk to all consumers. While consumers may not experience any short term health effects the result of longer term exposure to elevated levels of aluminium in potable waters may be a significant increase in the body burden of aluminium in these individuals. This artificially increased body burden will not return to ‘normal’ levels when the Al content of the potable water returns to normal but will act as a new platform level from which the Al body burden will continue to increase with age.

2008/13 – Bellbrook (New South Wales) – Turbidity

2008/13: Bellbrook (New South Wales) – Turbidity 11.5NTU (max), 0.81NTU (mean)

Chlorine-resistant pathogen reduction: Where filtration alone is used as the water treatment
process to address identified risks from Cryptosporidium and Giardia, it is essential
that filtration is optimised and consequently the target for the turbidity of water leaving
individual filters should be less than 0.2 NTU, and should not exceed 0.5 NTU at any time
Disinfection: A turbidity of less than 1 NTU is desirable at the time of disinfection with
chlorine unless a higher value can be validated in a specific context.

Aesthetic: Based on aesthetic considerations, the turbidity should not exceed 5 NTU at the
consumer’s tap

2008/13 Bellbrook (New South Wales) – Iron

2008/13: Bellbrook (New South Wales)  – Iron 0.31mg/L (max), 0.053 (mean)

Based on aesthetic considerations (precipitation of iron from solution and taste),
the concentration of iron in drinking water should not exceed 0.3 mg/L.
No health-based guideline value has been set for iron.

Iron has a taste threshold of about 0.3 mg/L in water, and becomes objectionable above 3 mg/L. High iron concentrations give water an undesirable rust-brown appearance and can cause staining of laundry and plumbing fittings, fouling of ion-exchange softeners, and blockages in irrigation systems. Growths of iron bacteria, which concentrate iron, may cause taste and odour problems and lead to pipe restrictions, blockages and corrosion. ADWG 2011

 

2008/13 – Bellbrook (New South Wales) – Aluminium, Turbidity, Iron, Selenium

Bellbrook – (NSW) – Selenium

2008-2013: Bellbrook Selenium 0.005mg/L (max), 0.0011mg/L (mean)

Based on health considerations, the concentration of selenium in drinking water should not exceed 0.004 mg/L (2011-2025 guideline 0.01mg/L). “General description Selenium (Se) and selenium salts are widespread in the environment. Selenium is released from natural and human-made sources (such as the burning of coal). Selenium is also a by-product of the processing of sulfide ores, chiefly in the copper refining industry. The major use of selenium is in the manufacture of electronic components. It is used in several other industries, and selenium compounds are used in some insecticides, in hair shampoos as an antidandruff agent, and as a nutritional feed additive for poultry and livestock. Selenium copper alloys have also been identified as a potential replacement for lead copper alloys in plumbing products. Further information on lead replacements in plumbing products (such as selenium copper alloys) is available in Information Sheet 4.1 – Metal and metalloid chemicals leaching from plumbing products. Selenium concentrations in drinking water source waters are generally very low and depend on local geochemistry, climatic conditions (e.g. drought), pH and the presence of iron salts. Selenium in water is mainly present as inorganic compounds, predominantly selenate. Weathering of rocks and soil may result in low levels of selenium in water, which may be taken up by plants (SLR 2022). Food is the major source of intake for Australians. Cereal and grain products contribute most to intake, while fish and liver contain the highest selenium concentrations.” ADWG 2025

Bellbrook (New South Wales) – Aluminium

2008/13: Bellbrook (New South Wales) Aluminium 0.61mg/L (max), 0.086mg/L (mean)
Australian Guideline: Aluminium 0.2mg/L

According to the ADWG, no health guideline has been adopted for Aluminium, but that the issue is still open to review. Aluminium can come from natural geological sources or from the use of aluminium salts as coagulants in water treatment plants. According to the ADWG “A well-operated water filtration plant (even using aluminium as a flocculant) can achieve aluminium concentrations in the finished water of less than 0.1 mg/L.

The most common form of aluminium in water treatment plants is Aluminium Sulfate (Alum). Alum can be supplied as a bulk liquid or in granular form. It is used at water treatment plants as a coagulant to remove turbidity, microorganisms, organic matter and inorganic chemicals. If water is particularly dirty an Alum dose of as high as 500mg/L could occur. There is also concern that other metals may also exist in refined alum.

While the ADWG mentions that there is considerable evidence that Aluminium is neurotoxic and can pass the gut barrier to accumulate in the blood, leading to a condition called encephalopathy (dialysis dementia) and that Aluminium has been associated with Parkinsonism dementia and amyotrophic lateral sclerosis, the NHMRC, whilst also acknowledging studies which have linked Aluminium with Alzheimer disease, has not granted Aluminium a NOEL (No Observable Effect Level) due to insufficient and contradictory data. Without a NOEL, a health guideline cannot be established. The NHMRC has also stated that if new information comes to hand, a health guideline may be established in the future.

In communication with Aluminium expert Dr Chris Exley (Professor in Bioinorganic Chemistry
The Birchall Centre, Lennard-Jones Laboratories, Keele University, Staffordshire UK) in March 2013 regarding high levels of Aluminium detected in the South Western Victorian town of Hamilton
“It is my opinion that any value above 0.5 mg/L is totally unacceptable and a potential health risk. Where such values are maintained over days, weeks or even months, as indeed is indicated by the data you sent to me, these represent a significant health risk to all consumers. While consumers may not experience any short term health effects the result of longer term exposure to elevated levels of aluminium in potable waters may be a significant increase in the body burden of aluminium in these individuals. This artificially increased body burden will not return to ‘normal’ levels when the Al content of the potable water returns to normal but will act as a new platform level from which the Al body burden will continue to increase with age.

2008/13 – Bellbrook (New South Wales) – Turbidity

2008/13: Bellbrook (New South Wales) – Turbidity 11.5NTU (max), 0.81NTU (mean)

Chlorine-resistant pathogen reduction: Where filtration alone is used as the water treatment
process to address identified risks from Cryptosporidium and Giardia, it is essential
that filtration is optimised and consequently the target for the turbidity of water leaving
individual filters should be less than 0.2 NTU, and should not exceed 0.5 NTU at any time
Disinfection: A turbidity of less than 1 NTU is desirable at the time of disinfection with
chlorine unless a higher value can be validated in a specific context.

Aesthetic: Based on aesthetic considerations, the turbidity should not exceed 5 NTU at the
consumer’s tap

2008/13 Bellbrook (New South Wales) – Iron

2008/13: Bellbrook (New South Wales)  – Iron 0.31mg/L (max), 0.053 (mean)

Based on aesthetic considerations (precipitation of iron from solution and taste),
the concentration of iron in drinking water should not exceed 0.3 mg/L.
No health-based guideline value has been set for iron.

Iron has a taste threshold of about 0.3 mg/L in water, and becomes objectionable above 3 mg/L. High iron concentrations give water an undesirable rust-brown appearance and can cause staining of laundry and plumbing fittings, fouling of ion-exchange softeners, and blockages in irrigation systems. Growths of iron bacteria, which concentrate iron, may cause taste and odour problems and lead to pipe restrictions, blockages and corrosion. ADWG 2011