Cox Peninsula (Northern Territory) – E.coli

2009/10: Cox Peninsula E. coli 1 exceedance 98.1% compliance during year

2010/11: Cox Peninsula E. coli 1 exceedance 98.0% compliance during year

“E.coli

Thermotolerant coliforms are a sub-group of coliforms that are able to grow at 44.5 ± 0.2°C. E. coli is the most common thermotolerant coliform present in faeces and is regarded as the most specific indicator of recent faecal contamination because generally it is not capable of growth in the environment. In contrast, some other thermotolerant coliforms (including strains of Klebsiella, Citrobacter and Enterobacter) are able to grow in the environment and their presence is not necessarily related to faecal contamination. While tests for thermotolerant coliforms can be simpler than for E. coli, E. coli is considered a superior indicator for detecting faecal contamination…” ADWG

Cox Peninsula (Northern Territory) – pH (acidic)

Average pH: 2005 July-2006 June: 5.2 pH units

Average pH: 2004 July-2005 June: 5.2 pH units

Based on the need to reduce corrosion and encrustation in pipes and fittings, the pH of
drinking water should be between 6.5 and 8.5.

New concrete tanks and cement-mortar lined pipes can significantly increase pH and
a value up to 9.2 may be tolerated, provided monitoring indicates no deterioration in
microbiological quality.

pH is a measure of the hydrogen ion concentration of water. It is measured on a logarithmic scale from 0 to 14. A pH of 7 is neutral, greater than 7 is alkaline, and less than 7 is acidic.

One of the major objectives in controlling pH is to minimise corrosion and encrustation in pipes and fittings. Corrosion can be reduced by the formation of a protective layer of calcium carbonate on the inside of the pipe or fitting, and the formation of this layer is affected by pH, temperature, the availability of calcium (hardness) and carbon dioxide. If the water is too alkaline (above pH 8.5), the rapid deposition and build-up of calcium carbonate that can result may eventually block the pipe.

Cox Peninsula (Northern Territory)  – Iron

2005/06: Cox Peninsula (Northern Territory)  – Iron 0.41mg/L (Highest level only)

2004/05: Cox Peninsula (Northern Territory)  – Iron 0.4mg/L (Highest level only)

Based on aesthetic considerations (precipitation of iron from solution and taste),
the concentration of iron in drinking water should not exceed 0.3 mg/L.
No health-based guideline value has been set for iron.

Iron has a taste threshold of about 0.3 mg/L in water, and becomes objectionable above 3 mg/L. High iron concentrations give water an undesirable rust-brown appearance and can cause staining of laundry and plumbing fittings, fouling of ion-exchange softeners, and blockages in irrigation systems. Growths of iron bacteria, which concentrate iron, may cause taste and odour problems and lead to pipe restrictions, blockages and corrosion. ADWG 2011

Cox Peninsula (Northern Territory) – Lead

2015/2016: Cox Peninsula Lead 0.004mg/L

Lead Guideline reduced from 0.01mg/L to 0.005mg/L in June 2025. “The concentration of lead in water within premises may be higher, especially in older buildings, due to contact of the water with lead-containing plumbing products (enHealth 2021). A review found several Australian and international studies that detected up to 0.162 mg/L of lead in drinking water due to leaching from lead-containing plumbing materials including taps and lead service lines, suggesting that leaching of lead from lead-containing plumbing materials can be substantial (SLR 2023)… Based on health considerations, the concentration of lead in drinking water should not exceed 0.005 mg/L.”

2004/16 – Cox Peninsula (Northern Territory) – E.coli, pH, Iron, Lead

Cox Peninsula (Northern Territory) – E.coli
2009/10: Cox Peninsula E. coli 1 exceedance 98.1% compliance during year 2010/11: Cox Peninsula E. coli 1 exceedance 98.0% compliance during year
“E.coli
Thermotolerant coliforms are a sub-group of coliforms that are able to grow at 44.5 ± 0.2°C. E. coli is the most common thermotolerant coliform present in faeces and is regarded as the most specific indicator of recent faecal contamination because generally it is not capable of growth in the environment. In contrast, some other thermotolerant coliforms (including strains of Klebsiella, Citrobacter and Enterobacter) are able to grow in the environment and their presence is not necessarily related to faecal contamination. While tests for thermotolerant coliforms can be simpler than for E. coli, E. coli is considered a superior indicator for detecting faecal contamination…” ADWG
2005/6: Cox Peninsula (Northern Territory) – pH (acidic) Average pH: 2005 July-2006 June: 5.2 pH units Average pH: 2004 July-2005 June: 5.2 pH units Based on the need to reduce corrosion and encrustation in pipes and fittings, the pH of drinking water should be between 6.5 and 8.5. New concrete tanks and cement-mortar lined pipes can significantly increase pH and a value up to 9.2 may be tolerated, provided monitoring indicates no deterioration in microbiological quality. pH is a measure of the hydrogen ion concentration of water. It is measured on a logarithmic scale from 0 to 14. A pH of 7 is neutral, greater than 7 is alkaline, and less than 7 is acidic. One of the major objectives in controlling pH is to minimise corrosion and encrustation in pipes and fittings. Corrosion can be reduced by the formation of a protective layer of calcium carbonate on the inside of the pipe or fitting, and the formation of this layer is affected by pH, temperature, the availability of calcium (hardness) and carbon dioxide. If the water is too alkaline (above pH 8.5), the rapid deposition and build-up of calcium carbonate that can result may eventually block the pipe. Cox Peninsula (Northern Territory)  – Iron 2005/06: Cox Peninsula (Northern Territory)  – Iron 0.41mg/L (Highest level only) 2004/05: Cox Peninsula (Northern Territory)  – Iron 0.4mg/L (Highest level only) Based on aesthetic considerations (precipitation of iron from solution and taste), the concentration of iron in drinking water should not exceed 0.3 mg/L. No health-based guideline value has been set for iron. Iron has a taste threshold of about 0.3 mg/L in water, and becomes objectionable above 3 mg/L. High iron concentrations give water an undesirable rust-brown appearance and can cause staining of laundry and plumbing fittings, fouling of ion-exchange softeners, and blockages in irrigation systems. Growths of iron bacteria, which concentrate iron, may cause taste and odour problems and lead to pipe restrictions, blockages and corrosion. ADWG 2011 Cox Peninsula (Northern Territory) – Lead 2015/2016: Cox Peninsula Lead 0.004mg/L Lead Guideline reduced from 0.01mg/L to 0.005mg/L in June 2025. “The concentration of lead in water within premises may be higher, especially in older buildings, due to contact of the water with lead-containing plumbing products (enHealth 2021). A review found several Australian and international studies that detected up to 0.162 mg/L of lead in drinking water due to leaching from lead-containing plumbing materials including taps and lead service lines, suggesting that leaching of lead from lead-containing plumbing materials can be substantial (SLR 2023)… Based on health considerations, the concentration of lead in drinking water should not exceed 0.005 mg/L.”