2016/17+ 2022/23 – Freeling (South Australia) – NDMA, Ammonia, pH

Freeling (South Australia) – NDMA

3/11/22 Freeling (South Australia) NDMA 193ng/L, 43ng/L (av. 2022/23)

“Based on health considerations, the concentration of NDMA in drinking water should not
exceed 0.0001 mg/L (100 ng/L). Action to reduce NDMA is encouraged, but must not compromise disinfection, as non disinfected water poses significantly greater risk than NDMA.

NDMA is used as an industrial solvent, an anti-oxidant, a rubber accelerator, and in the preparation of polymers, where it may be used as an initiator or a plasticiser. The compound has been used in the production of rocket fuel, as a biocide for nematodes, and an intermediate for 1,1-dimethylhydrazine to inhibit nitrification of soils.

NDMA is formed under mildly acidic conditions by the reaction of natural and synthetic secondary, tertiary or quaternary amines with nitrate and nitrite. Precursor amines include alkylamines, dimethylamine (DMA), tetramethylthiuram disulfide (thiram) and polyelectrolytes used in water and wastewater treatment. NDMA is also produced as a by-product of chloramination of drinking water (due to the presence of dimethylamine in source waters subject to wastewater discharges or the oxidation of natural organic matter by chlorine in the presence of ammonia) and to a lesser extent by chlorination. NDMA formation can be facilitated in soils by biochemical pathways in micro-organisms, and this compound is resistant to microbial degradation under both aerobic and anaerobic conditions. Ozonation of drinking water contaminated with the fungicide tolyfluamide can also lead to the formation of NDMA…

TYPICAL VALUES IN AUSTRALIAN DRINKING WATER
There are no data in the public domain or peer reviewed literature on NDMA in Australian drinking water distribution systems and water treatment plants. Anecdotal evidence suggests a bi-modal distribution, with several water authorities indicating that NDMA is present at levels at or near the limit of determination of 1 to 2 ng/L, whereas preliminary sampling and analysis by other authorities indicates levels in the range of 60-90 ng/L. A recent report from South Australia has indicated that NDMA may originate from rubber components of newly commissioned drinking water pipelines, regardless of the disinfectant used. This
may account at least partly for the divergent results reported by different water suppliers…” ADWG 2011

Freeling (South Australia) – Ammonia

January 5 2017 – Freeling (South Australia) Ammonia Free as NH3 0.56mg/L

8/11/18: Freeling (South Australia) Ammonia 0.51mg/L (max for 2018/19)

Based on aesthetic considerations (corrosion of copper pipes and fittings), the concentration
of ammonia (measured as ammonia) in drinking water should not exceed 0.5 mg/L.
No health-based guideline value is set for ammonia.

“…Most uncontaminated source waters have ammonia concentrations below 0.2 mg/L. High concentrations (greater than 10 mg/L) have been reported where water is contaminated with animal waste. Ammonia is unlikely to be detected in chlorinated supplies as it reacts quickly with free chlorine. Ammonia in water can result in the corrosion of copper pipes and fittings, causing copper stains on sanitary ware. It is also a food source for some microorganisms, and can support nuisance growths of bacteria and algae, often with a resultant increase in the nitrite concentration.” ADWG 2011

Freeling (South Australia) – pH (alkaline)

Average pH: 2016 July-2017 June: 8.883 pH units

Based on the need to reduce corrosion and encrustation in pipes and fittings, the pH of
drinking water should be between 6.5 and 8.5.

New concrete tanks and cement-mortar lined pipes can significantly increase pH and
a value up to 9.2 may be tolerated, provided monitoring indicates no deterioration in
microbiological quality.

pH is a measure of the hydrogen ion concentration of water. It is measured on a logarithmic scale from 0 to 14. A pH of 7 is neutral, greater than 7 is alkaline, and less than 7 is acidic.

One of the major objectives in controlling pH is to minimise corrosion and encrustation in pipes and fittings. Corrosion can be reduced by the formation of a protective layer of calcium carbonate on the inside of the pipe or fitting, and the formation of this layer is affected by pH, temperature, the availability of calcium (hardness) and carbon dioxide. If the water is too alkaline (above pH 8.5), the rapid deposition and build-up of calcium carbonate that can result may eventually block the pipe.

When pH is below 6.5 or above 11, the water may corrode plumbing fittings and pipes. This, however, will depend on other factors such as the material used, the concentration and type of ions in solution, the availability of oxygen, and the water temperature. Under some conditions, particularly in the presence of strong oxidising agents such as chlorine, water with a pH between 6.5 and 7 can be quite corrosive.

Chlorine disinfection efficiency is impaired above pH 8.0, although the optimum pH for monochloramine disinfectant formation is between 8.0 and 8.4. In chloraminated supplies chlorine can react with ammonia to form odorous nitrogen trichloride below pH 7.

Chlorination of water supplies can decrease the pH, while it can be significantly raised by lime leached from new concrete tanks or from pipes lined with asbestos cement or cement mortar. Values of pH above 9.5 can cause a bitter taste in drinking water, and can irritate skin if the water is used for ablutions.